Whirlpool Water Heater Checkins

All Brands > Whirlpool > Checkins > Repair

Average Lifespan: 12.1 Years
Rating: 3.6/5 stars out of 11 ratings.
more info...

Near W 72nd St, Shawnee, KS 66216  
WHIRLPOOL
Model
Rating
Age
8 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK

New
Near Sherwood Rd, Leawood, KS 66224  
WHIRLPOOL
Model
BFG2J5040T3NOV
Rating
Age
8 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK

New Bradford White water heater installed and 4" flue put in. There was also a new expansion tank and PRV installed.
Near NW 64th St, Gladstone, MO 64118  
WHIRLPOOL
Model
FG1H4040T3
Rating
Age
12 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT

New AO Smith 40 gallon short gas water heater installed.
Near Ballentine St, Shawnee, KS 66203  
WHIRLPOOL
Model
BFG6140T423565
Rating
Age
7 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
water damage

bad slope
AO Smith short installed in Shawnee
A new AO Smith short 40 gallon was installed. The tank was elevated off the floor and a solid wood platform was used to ensure that intake did not bypass the air filter. The flue was also redone all the way back to the furnace in order to allow for more slope. A new shutoff was installed for both the gas and water.
Near Oliver St, Kansas City, KS 66106  
WHIRLPOOL
Model
F4040S3NOV
Rating
Age
12 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT

Whirlpool tank with pilot issues
New AO Smith installed on this open system. Gas shutoff was replaced and installed above the flexible supply line for the gas.
Near W 61st St, Shawnee, KS 66216  
WHIRLPOOL
Model
BFG1F3030S3NOV
Rating
Age
10 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
basement flooded

Whirlpool sucks
short hot water tank
The new water heater was installed on blocks to prevent damage from future possible floods.
Near S Summertree Ln, Olathe, KS 66062  
WHIRLPOOL
Model
FG1H4040T3NOV
Rating
Age
13 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE

leaking whirlpool water heater
water heater
Water heater warranty
New AO Smith GCR50400 water heater installed. New shutoff installed on gas line.
Near N London Dr, Kansas City, MO 64151  
WHIRLPOOL
Model
CRGVF8533T
Rating
Age
26 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK

thermal expansion tank supported by water heater
A new pressure reducing valve installed along with thermal expansion tank. New shutoffs also installed and pressure was reduced from high levels.
Near N Lydia Ave, Kansas City, MO 64155  
WHIRLPOOL
Model
Rating
Age
18 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK

New AO Smith water heater installed with thermal expansion tank and new PRV.
Near N Harrison St, Gladstone, MO 64118  
WHIRLPOOL
Model
BFG1F4034T3NOV
Rating
Age
7 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT

New AO Smith installed and the flexible gas supply line was also removed. The flue was also adjusted to have the proper connections and slope. The old flue had a 3\" pipe going into a 4\" flue with no reducer coupling.
Near Bradshaw St, Shawnee, KS 66216  
WHIRLPOOL
Model
Rating
Age
11 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK

New
Near Hauser St, Lenexa, KS 66215  
WHIRLPOOL
Model
FG1F4034T3NOV
Rating
Age
13 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT

Installed new heater to replace a pilot issue.
Near W 156th Ter, Overland Park, KS 66221  
WHIRLPOOL
Model
FG1H4040T3NOV
Rating
Age
11 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
low hot water

Install a new 50 gallon tank, decided to switch to AO Smith 40,000 BTU burner which produced far more hot water.
Near Beirut Cir, Kansas City, MO 64153  
WHIRLPOOL
Model
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK

Installed two AO Smith energy efficient hot water heaters.
Near Ballentine St, Overland Park, KS 66214  
WHIRLPOOL
Model
G1H5035T3NV
Rating
Age
14 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK

Install new AO Smith water heater.
Near Belinder Rd, Westwood, KS 66205  
WHIRLPOOL
Model
BFG1F4034T3NOV
Rating
Age
15 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT

Install short 40 gallon Bradford White hot water heater along with a 5\" flue liner for the chimney. The short tank created a much better draw.
Near N 150th St, Basehor, KS 66007  
WHIRLPOOL
Model
G1F4034T3NV
Rating
Age
13 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE

Install new AO Smith GCG-50-400 water heater with new shutoff valve. Also replaced some shutoff valves for the upstairs washing machine.
Near Wood Ave, Kansas City, KS 66104  
WHIRLPOOL
Model
FG1F4040S3NOV
Rating
Age
10 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT

Installed GCG 50 400 AO Smith. Installed new shutoff and drip leg on gas line.