All Brands > Bradford White > Checkins > Repair
Bradford White Checkins
Average Lifespan: 15.9 Years
Rating: 4/5 stars out of 38 ratings.
more info...Near NE 50th St, Kansas City, MO 64119
BRADFORD WHITE
Model
Rating
Age
25 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New
Near Reeder St, Overland Park, KS 66221
BRADFORD WHITE
Model
Rating
Age
20 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near W 74th St, Shawnee, KS 66216
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
23 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
The new setup consist of only a single high recovery water heater. Going from 2 down to 1 tank can save over $5,000 over the lifespan of the water heater.
Near Beverly Dr, Overland Park, KS 66207
BRADFORD WHITE
Model
Rating
Age
22 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
GAS VALVE / PILOT
New
Near N Persimmon Dr, Olathe, KS 66061
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
19 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
A new 4" vent connector was installed for both the water heater and furnace. Thermal expansion tank, PRV, and new main shutoff was installed.
Near W 126th Ter, Overland Park, KS 66209
BRADFORD WHITE
Model
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near NW Cottonwood Dr, Lee's Summit, MO 64064
BRADFORD WHITE
Model
Rating
Age
28 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near W 140th Pl, Overland Park, KS 66221
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
22 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
Everything including the venting was replaced. The vent was upsized from 3" to 4", the vent material was originally 30ga metal and was replaced with 26ga metal. A rise off the top of the tank before the first vent elbow was also added.The entire water heater, gas line, and water lines were moved back about 18" to reduce the horizontal vent span. Moving the tank also made more space in the mechanical room.A thermal expansion tank was installed and set to 73 psi. The expansion tank was strapped to the wall. A new PRV was also installed in the entire house. I'll go ahead and say it, this is a rockstar installation by KC Water Heaters.
Near S Greenwood St, Olathe, KS 66062
BRADFORD WHITE
Model
Rating
Age
25 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Brownridge Dr, Shawnee, KS 66218
BRADFORD WHITE
Model
Rating
Age
17 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near NW 77th Ter, Kansas City, MO 64152
BRADFORD WHITE
Model
Rating
Age
21 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Foster St, Overland Park, KS 66223
BRADFORD WHITE
Model
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Bond St, Overland Park, KS 66221
BRADFORD WHITE
Model
Rating
Age
21 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
A PRV had been replaced a few years back. The venting was replaced and a 4" wye and vent was installed.
Near Hilltop Dr, Shawnee, KS 66226
BRADFORD WHITE
Model
Rating
Age
21 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Haven St, Lenexa, KS 66219
BRADFORD WHITE
Model
Rating
Age
18 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near W 157th Pl, Overland Park, KS 66224
BRADFORD WHITE
Model
Rating
Age
21 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Benson St, Overland Park, KS 66221
BRADFORD WHITE
Model
Rating
Age
20 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near W 121st Ter, Olathe, KS 66062
BRADFORD WHITE
Model
Rating
Age
21 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New
Near Haskins St, Overland Park, KS 66213
BRADFORD WHITE
Model
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Earnshaw St, Overland Park, KS 66213
BRADFORD WHITE
Model
Rating
Age
22 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Ballentine St, Overland Park, KS 66221
BRADFORD WHITE
Model
Rating
Age
24 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near Conser St, Overland Park, KS 66223
BRADFORD WHITE
Model
Rating
Age
18 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near W 172nd St, Gardner, KS 66030
BRADFORD WHITE
Model
Rating
Age
8 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near N Skiles Ave, Kansas City, MO 64157
BRADFORD WHITE
Model
Rating
Age
11 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near River Run Dr, Platte City, MO 64079
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
18 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
A new PRV was installed along with an AO Smith GCR 50 gallon water heater. The main shutoff was also bad and would not allow the water to shut off all the way or for full water volume into the house. A new gas and water shutoff was installed along with a thermal expansion tank. The flue was also redone to allow for more rise off the top of the water heater.
Near W 68th Ter, Prairie Village, KS 66208
BRADFORD WHITE
Model
MI5036FBN4
Rating
Age
12 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New AO Smith installed. Opening in chimney was capped off. Most difficult part about this install was getting the tanks down the small stairway in this older home.
Near Earnshaw St, Shawnee, KS 66216
BRADFORD WHITE
Model
MI403T6EN12
Rating
Age
18 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New AO Smith water heater installed and the humidifier line was replaced.
Near N Polk Ave, Kansas City, MO 64154
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
20 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
The PRV was removed and the new water heater was installed without a thermal expansion tank.
Near Lone Elm Rd, Shawnee, KS 66218
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
13 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
The PRV was replaced as well as the thermal expansion tank. The PRV was also moved up above the spigot to allow the ability to monitor the incoming water pressure. New shutoff installed for water heater and humidifier.
Near S Widmer St, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036FBN2
Rating
Age
13 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
Flue was redone to increase the ability to draw. The PRV was also replaced and the humidifier valve was replaced with a compression stop.
Near Cottonwood Dr, Shawnee, KS 66216
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
GAS VALVE / PILOT
New PRV installed to reduce water pressure down to 75 psi. AO Smith water heater installed and the saddle valves for the humidifier and fridge were replaced.
Near NE 78th St, Kansas City, MO 64118
BRADFORD WHITE
Model
MI40T6FBN7
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith installed in place of the two tanks. The PRV was also bad and was replaced during the water heater install. There was also a thermal expansion tank installed.
Near N Beaman Ave, Kansas City, MO 64151
BRADFORD WHITE
Model
MI40T5LN10
Rating
Age
24 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
AO Smith water heater installed along with thermal expansion tank and new PRV. The line for the humidifier was also replaced with a full brass body compression valve which was also lead free. The water pressure was set to 75 psi and the expansion tank was also set to 75 psi.
Near W 121st St, Overland Park, KS 66213
BRADFORD WHITE
Model
MI5036FBN7
Rating
Age
11 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
A new PRV was installed to lower the water pressure to 75 psi, thus creating a closed system. A thermal expansion tank was installed on the new water heater. The main shutoff was also replaced as the old valve did not completely shutoff the water.
Near Timber Ln, Bonner Springs, KS 66012
BRADFORD WHITE
Model
MI5036FBN7
Rating
Age
11 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith water heater installed. Flue was redone to improve drafting. Homeowner was also advised to contact water company to request for the check valve to be removed from the water heater.
Near NW 84th Ter, Kansas City, MO 64154
BRADFORD WHITE
Model
MI40S6DS13
Rating
Age
23 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith electric water heater installed. PRV was more than 20 years old as well and no longer necessary with water pressure below 80.
Near NE Moonstone Dr, Lee's Summit, MO 64064
BRADFORD WHITE
Model
MI40T6DS13
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New Bradford White 40 gallon electric water heater installed and PRV replaced.
Near Conser St, Overland Park, KS 66212
BRADFORD WHITE
Model
MI403T6EN12
Rating
Age
15 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New AO Smith installed and the main shutoff was replaced despite being hard to access with the finished basement. A small hole was cut into the drywall.
Near Albervan St, Shawnee, KS 66216
BRADFORD WHITE
Model
MI40T6FBN
Rating
Age
8 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
The water pressure was low enough to remove the PRV and revert back to an open system.
Near Aminda St, Shawnee, KS 66226
BRADFORD WHITE
Model
MI5036FBN7
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
AO Smith GCR50400 installed in place of the Bradford White.
Near S Kaw Dr, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
15 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New water heater installed and new copper added to clean things up. Also rerouted the flue to keep away from the PVC vented furnace.
Near E 36th St, Kansas City, MO 64109
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
13 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
Old flue, gas line, and water lines capped off and went back to a more practical single tank. Water pressure was about 70 psi and on an open system. Hopefully the new tank lasts 15-20 years.
Near King St, Overland Park, KS 66213
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
The PRV was installed above the spigot which allowed the water pressure to be checked before the PRV. The pressure was only 80 psi. Faced with the decision to either replace or remove the PRV, they decided to remove it. This made the house an open system and a thermal expansion tank was not needed.
Near Antioch Rd, Overland Park, KS 66212
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
14 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
A new AO Smith was installed. The copper gas line was replaced with iron pipe. A thermal expansion tank and PRV is needed when the pressure is this high.
Near N Prospect Ave, Kansas City, MO 64119
BRADFORD WHITE
Model
MI5036FBN
Rating
Age
8 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
AO Smith GCR model replaced the Bradford White and a thermal expansion tank was installed. Also installed new water shutoff valve. Pressure Reducing Valve was easily accessible so that was replaced also.
Near W 139th Ter, Leawood, KS 66224
BRADFORD WHITE
Model
MI50T6DS13
Rating
Age
18 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
New AO Smith electric water heater installed and thermal expansion tank put in. The water pressure was too high in this building so a PRV will be installed.
Near S Holloway Rd, Oak Grove, MO 64075
BRADFORD WHITE
Model
MI40T6CX12
Rating
Age
14 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New AO Smith GCG 50 401 propane water heater installed. There were two major things we found on this job. The first was a gas leak on the line to the furnace. This was caught and repaired. The second issue was a loose flue pipe which could cause carbon monoxide to dump into the house.
Near W 145th Ter, Olathe, KS 66061
BRADFORD WHITE
Model
MI5036FBN
Rating
Age
9 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
AO Smith hot water heater installed on open system and new shutoff valves put in.
Near Shawnee Mission Pkwy, Fairway, KS 66205
BRADFORD WHITE
Model
MI5035LN8
Rating
Age
25 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
The new AO Smith was installed and the recirculating line was hooked back up.
Near N Eastern Ave, Kansas City, MO 64157
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
15 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith GCR water heater installed along with thermal expansion tank. Expansion tank inflated to 75 psi and new shutoffs installed.
Near W 112th St, Leawood, KS 66211
BRADFORD WHITE
Model
M1XR65T6EN10
Rating
Age
17 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith installed and a 4 gallon Amtrol expansion tank added in this Leawood home.
Near Sagamore Rd, Leawood, KS 66206
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
23 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
We discussed the needs with the client and decided that they would be better off with only one 50 gallon tank opposed to two separate tanks. Upon installing the new water heater we found a baseball size hole in the backside of the flue that was not visible unless the flue was taken apart. These water heaters were almost certainly dumping Carbon Monoxide inside of this families home. We replaced the entire section of flue and installed a PRV.
Near S Deer Run St, Olathe, KS 66061
BRADFORD WHITE
Model
MI5036FBN
Rating
Age
8 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
A thermal expansion tank was installed along with the GCR 50 400 from AO Smith.
Near Goodman Dr, Merriam, KS 66202
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT
A new Bradford White was installed along with a new main shutoff valve that was located behind the existing water heater.
Near NW 75th St, Kansas City, MO 64118
BRADFORD WHITE
Model
MI403T6EN12
Rating
Age
17 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith GCR higher efficiency and heavier tank installed in place of a 17 year old Bradford White tank. The saddle valve for the humidifier was also removed and replaced with a full port angle stop.
Near Aberdeen Rd, Leawood, KS 66209
BRADFORD WHITE
Model
MI504S6EN10
Rating
Age
16 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith installed in place of Bradford White hot water heater.
Near White Oak Ln, Liberty, MO 64068
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
A 50 gallon 40,000 BTU burner was installed. New shutoff also installed and the PRV was replaced.
Near W 98th Ter, Lenexa, KS 66220
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Pressure Reducing Valve was replaced two saddle valves were removed. The thermal expansion tank was inflated to 75 psi and the water pressure was also set to 75.
Near SW Soldier Ct, Lee's Summit, MO 64082
BRADFORD WHITE
Model
MI5036FBN7
Rating
Age
11 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New PRV installed along with thermal expansion tank. AO Smith GCR 50 400 is a more efficient, heavy duty water heater.
Near W 50th St, Westwood, KS 66205
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
19 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
Installation of AO Smith water heater. The copper gas line was removed and replaced with iron pipe. New shutoff installed along with copper supply lines.
Near Linden St, Overland Park, KS 66224
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
14 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
Thermal expansion tank installed along with new main water shutoff valve.
Near W 81st Ter, Lenexa, KS 66219
BRADFORD WHITE
Model
NORT97150
Rating
Age
16 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
GAS VALVE / PILOT
The new AO Smith was turned to face the front of the room when you walked in and the flue was increased to a 4" diameter. This tank was leveled and caulked to the floor.
Near N Kenwood Ave, Kansas City, MO 64155
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
20 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New water heater installed in the garage made for a quick replacement. Anytime you can back right up to the water heater being replaced and don't have steps it makes for an easy install.
Near S Gardner Rd, Spring Hill, KS 66083
BRADFORD WHITE
Model
MI50T6DS13
Rating
Age
15 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
New Hybrid Electric water heater from AO Smith is over $350 per year lower in operational cost when compared to a standard electric water heater.
Near W 94th Ter, Lenexa, KS 66220
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith water heater installed without thermal expansion tank, Lenexa does not require thermal expansion tanks on water heater replacements. Since the old tank lasted 18 years the owner opted not to install a thermal expansion tank on the new unit due to the maintenance that a thermal expansion tank requires.
Near Manor Dr, Parkville, MO 64152
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith installed and new PRV installed in home.
Near Flint St, Overland Park, KS 66213
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
New Craftmaster water heater installed and was provided by homeowner. This water heater has an air induced fan to increase efficiency. A thermal expansion tank was installed to help increase the life of the new tank.
Near W 83rd Ter, Lenexa, KS 66219
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
20 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
The new tank took under 4 minutes to fill which is up to a minute faster than many other homes. Flexible gas line was removed and new gas cock installed.
Near E 192nd St, Belton, MO 64012
BRADFORD WHITE
Model
MI50S6D513
Rating
Age
20 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
New AO Smith ENT 50 100 electric water heater puts out 71 gallons of hot water for the first hour. New shutoff valve was also installed.
Near Marty St, Overland Park, KS 66204
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
20 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New AO Smith water heater went in as a replacement. This 40 gallon water heater is more efficient than the previous tank and copper supply lines were installed.
Near S Sioux Ct, Independence, MO 64057
BRADFORD WHITE
Model
MI5036FBN4
Rating
Age
11 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith water heater installed along with thermal expansion tank and new PRV.
Near N Overlook St, Olathe, KS 66061
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New Bradford White installed and flue was corrected.
Near N Hardesty Ave, Kansas City, MO 64119
BRADFORD WHITE
Model
MI40T6FBN2
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Two AO Smith GCR 50 400 Higher Efficiency gas water heaters installed to replace the old tanks. The piping was cut out and replaced to establish a parallel system. The parallel setup for multiple water heaters will maximize performance and will also allow you to shut down one of the units while still providing hot water.
Near W 156th St, Overland Park, KS 66223
BRADFORD WHITE
Model
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New
Near W 154th St, Overland Park, KS 66223
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
17 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Barely enough room to install a thermal expansion tank behind the full port ball valve. You should always replace old valves with brass free fittings.
Near N Diane Dr, Olathe, KS 66061
BRADFORD WHITE
Model
MI5036FBN4
Rating
Age
12 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New water heater was installed and the water lines were hard piped with 3/4\" copper. A new full port ball valve was installed and the gas line was hard piped. The valve for the humidifier was also replaced.
Near E Duffey Ct, Independence, MO 64055
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
15 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New water heater and thermal expansion tank was installed. Flex gas supply line was removed and replaced with iron pipe.
Near S Skyview Ln, Olathe, KS 66061
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
17 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
New AO Smith was installed, plumber forgot to take photo of the new installation.
Near NE 98th St, Kansas City, MO 64157
BRADFORD WHITE
Model
MI40T6FBN4
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
GAS VALVE / PILOT
AO Smith hot water heater was installed along with Amtrol thermal expansion tank. This house was piped in CPVC which is always a unique challenge when connecting to.
Near W 130th Ter, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036LN10
Rating
Age
18 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
Install new AO Smith water heater and replace two saddle valves.
Near NW Prairie View Rd, Kansas City, MO 64151
BRADFORD WHITE
Model
MI40T6FBN4
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith water heater and thermal expansion tank as required by code.
Near W 154th St, Overland Park, KS 66224
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
14 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
Install two new 40 gallon GCR40400 AO Smith tanks. Also replaced two saddle valves and installed a 4 gallon thermal expansion tank. The water heater was also moved back to provide more room for walking.
Near NE 48th Ter, Kansas City, MO 64119
BRADFORD WHITE
Model
MI40T6FBN4
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install short 40 gallon water heater to prevent carbon monoxide.
Near NW 62nd Ter, Kansas City, MO 64118
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
21 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith water heater along with thermal expansion tank.
Near S Freedom St, Olathe, KS 66061
BRADFORD WHITE
Model
MI5036FBN7
Rating
Age
9 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
A thermal expansion tank was installed with the new AO Smith GCR 50 400 hot water heater. The saddle valve was replaced with an angle stop and moved to the cold side. Most humidifiers should be feed from the cold side instead of the hot.
Near W 75th Ter, Prairie Village, KS 66208
BRADFORD WHITE
Model
MI40T6FBN4
Rating
Age
11 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith 50 gallon hot water heater and install a thermal expansion tank to help regulate high water pressure. The relief valve of the old water heater had leaked due to thermal expansion.
Near N Mercier Ave, Kansas City, MO 64118
BRADFORD WHITE
Model
MI40T6FBN
Rating
Age
9 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith and an Amtrol thermal expansion tank.
Near Wedd St, Overland Park, KS 66221
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO water heaters and large thermal expansion tank.
Near W 89th St, Lenexa, KS 66220
BRADFORD WHITE
Model
MI5036FBN
Rating
Age
7 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new State Select water heater and installed new shutoffs.
Near NW 83rd Ter, Kansas City, MO 64152
BRADFORD WHITE
Model
MI40T6LN10
Rating
Age
27 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith water heater and thermal expansion tank.
Near Chadwick St, Leawood, KS 66224
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith water heater.
Near N 111th St, Kansas City, KS 66109
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install AO Smith and hard pipe gas line as well as add a thermal expansion tank.
Near S Hallet St, Olathe, KS 66062
BRADFORD WHITE
Model
Rating
Age
19 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
AO Smith GCG50400 installed.
Near W 141st Ter, Leawood, KS 66224
BRADFORD WHITE
Model
MI5036FBN2
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith water heater and new pressure reducing valve.
Near S Mullen St, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
14 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith 50 gallon water heater and thermal expansion tank with isolation valve. The humidifier shutoff was also replaced.
Near W 150th Ct, Olathe, KS 66062
BRADFORD WHITE
Model
MI403T6EN12
Rating
Age
15 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
Install new AO Smith GCR 40 400 water heater. House did not have PRV and was on an open system.
Near Kansas Ave, Kansas City, KS 66106
BRADFORD WHITE
Model
M250T6DS-1NCWW
Rating
Age
6 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new AO Smith and Amtrol thermal expansion tank.
Near NE 113th St, Kansas City, MO 64155
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
15 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
Install new State 50 gallon gas water heater.
Near W 158th St, Overland Park, KS 66224
BRADFORD WHITE
Model
MI40T6EN12
Rating
Age
15 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install two AO Smith water heaters along with a 4 gallon Amtrol thermal expansion tank.
Near W 145th Ter, Leawood, KS 66224
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
13 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new State and replace a saddle valve with a quarter turn ball valve.
Near Charlotte St, Kansas City, MO 64146
BRADFORD WHITE
Model
MI40T6FBN
Rating
Age
6 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new GCR 40 400 AO Smith hot water heater along with a bonding clamp to reduce the negative impact that a water softener will have when paired with copper supply lines.
Near S Blackfeather St, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
19 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
Install new 50 gallon AO Smith and lead free Nibco ball valve.
Near W 83rd Pl, Lenexa, KS 66215
BRADFORD WHITE
Model
MI40T6FBN
Rating
Age
6 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
VENTING / INSTALLATION
Install a State Select power vent.
Near W 97th Ter, Lenexa, KS 66220
BRADFORD WHITE
Model
MI5036FBN2
Rating
Age
12 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
VENTING / INSTALLATION
Install new AO Smith along with full port ball valve.
Near Woodstock St, Shawnee, KS 66218
BRADFORD WHITE
Model
MI5036FBN4
Rating
Age
11 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith installed. A thermal expansion test showed that the water pressure rose to 97 psi when the tank was increasing in temperature and then seemed to level off at that point. A thermal expansion was not installed as it\'s not required in Shawnee and the maintenance was not wanted.
Near W 130th Pl, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
Installed a new GCG 50 400 AO Smith 50 gallon water heater. Replaced the saddle valve with a 1/4\" ball valve. The flue was adjusted to increase the slope of the water heater.
Near S Blackfeather St, Olathe, KS 66062
BRADFORD WHITE
Model
MI5036EN10
Rating
Age
16 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
LEAK
Installed new Bradford White MI5036FBN with new shutoffs.
Near Nieman Pl, Overland Park, KS 66214
BRADFORD WHITE
Model
MI5036FBN7
Rating
Age
10 Years
Open/Closed Loop
CLOSED LOOP
Reason for Replacement
LEAK
New AO Smith GCG-50-400 water heater installed. A thermal expansion tank was not required for this installation due to an open system and an incoming water pressure of 55 psi.
Near N Purdom St, Olathe, KS 66061
BRADFORD WHITE
Model
MITW50L6LN10
Rating
Age
20 Years
Open/Closed Loop
OPEN LOOP
Reason for Replacement
PRETENTATIVE MAINTENANCE
New shutoff valves and ice maker stops installed.